Technical Guidance on the Evaluation of Septic Tank Construction in District X

Authors

  • sitti safiatus riskijah State Polytechnic of Malang image/svg+xml
  • Agustin Dita Lestari
  • Moch Khamim
  • M. Zenurianto
  • Suselo Utoyo

DOI:

https://doi.org/10.57203/abdiwangi.v4i1.2026.%25p

Keywords:

Septic tank, evaluation, shape, dimensions, distance

Abstract

The construction of septic tanks in Area X was carried out by contract laborers. It is estimated that the septic tanks do not meet the requirements regarding their distance from drinking water wells, as well as their shape and construction dimensions. Therefore, technical guidance is needed to evaluate the construction of septic tanks in accordance with SNI 2398:2017 and to determine solutions in the event of non-compliance. The evaluation results show that 49% of existing sanitation facilities are in good condition and 51% require the construction of properly built septic tanks; there are 14 newly constructed septic tanks made of reinforced concrete with a mix ratio of 1PC:2Ps:3Krk and a 10 cm-thick plaster finish, with an average length and width of 1.2 m and a height of 2 m. Regarding the condition of the new septic tanks, 84% met the requirements; 2 septic tanks met the minimum distance requirement (10 m) from the clean water well; 12 units met the capacity requirement, and 2 units did not yet meet it but this can be addressed by shortening the pumping interval to every 3 years; the length-to-width ratio requirement has not yet been met, but the depth exceeds the minimum requirement, so 86% of the tanks meet the capacity requirement. It is recommended that future septic tanks be constructed with a length of 1.6 m, a width of 0.80 m, and a depth of 1.78 m, with construction and spacing in accordance with the requirements.

Downloads

Download data is not yet available.

References

[1] Amin, S., & Fahmi, E. (2021). Tantangan penanganan permukiman kumuh dari sudut pandang institusional: Studi kasuskolektif di Kel. Bintaro dan Kel. Banjar Kota Mataram. Jurnal Muara Sains, Teknologi, Kedokteran Dan Ilmu Kesehatan, 5(2), 485. https://doi.org/10.24912/jmstkik.v5i2.12133.

[2] Hasanawi, A., Masturi, H., & Hasanawi, A. (2019). Improvement of community governance to support slum upgrading in indonesia. Jurnal Perencanaan Pembangunan: The Indonesian Journal of Development Planning, 3(3), 347–358. https://doi.org/10.36574/jpp.v3i3.88.

[3] Wijayanti, D.P., Sutikno, F. R., & Surjono. (2023). Faktor-Faktor Yang Mempengaruhi Penanganan Sanitasi Pada Permukiman Kumuh Di Sempadan Sungai Kelurahan Kotalama, Kota Malang. JCES (Journal of Character Education Society). http://journal.ummat.ac.id/index.php/JCES.

[4] Ishartono, & Raharjo, S. T. (2016). The Sustainable Development Goals (SDG). Social Work Jurnal, 6, 154–272. https://doi.org/10.1201/9781003080220-8.

[5] Kristina, D. (2013). Upaya badan perencanaan pembangunan daerah kota malang dalam penataan permukiman di daerah sempadan sungai. 15(2), 1–23. https://mill.onesearch.id/Author/Home?author=Kristina%2C+Dewi%3B+Fakultas+Hukum+Universitas+Brawijaya.

[6] Lusiana, N., Widiatmono, B. R., & Luthfiyana, H. (2020). Beban Pencemaran BOD dan Karakteristik Oksigen Terlarut di Sungai Brantas Kota Malang. Jurnal Ilmu Lingkungan, 18(2), 354–366. https://doi.org/10.14710/jil.18.2.354-366.

[7] SNI 2398:2017. Tata cara perencanaan tangki septik dengan pengolahan lanjutan (sumur resapan, bidang resapan, up flow filter, kolam sanita). Diakses dari https://akses-sni.bsn.go.id/dokumen/2017/SNI%202398-2017/